9907-147 Woodward ProTech-203 Datasheet & Technical ManualWoodward 9907 147 ProTech 203 Series The Woodward 9907 147, also cataloged as the 9907 147 Overspeed Protection System, operates as a dedicated hardware component for high integrity prime mover overspeed monitoring within ProTech 203 network platforms. Hardware Specifications Parameter Specification Model 9907 147 Brand Woodward Origin United States Weight 6. 5 kg Dimensions 482. 6 mm x 310. 4 mm x 142. 7 mm Operating Temp 15 to +60 deg C Power
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Woodward 9907-147 ProTech-203 Series

The Woodward 9907-147, also cataloged as the 9907-147 Overspeed Protection System, operates as a dedicated hardware component for high-integrity prime mover overspeed monitoring within ProTech-203 network platforms.

Hardware Specifications

Parameter Specification
Model 9907-147
Brand Woodward
Origin United States
Weight 6.5 kg
Dimensions 482.6 mm x 310.4 mm x 142.7 mm
Operating Temp -15 to +60 deg C
Power Consumption 24 VDC (18-32 VDC Operating Range)
System Redundancy Triple Modular Redundant (TMR) / 2oo3 Voting Logic
Trip Configuration De-Energize-to-Trip (DET) / Fail-Safe Logic
Speed Inputs 3 Independent Magnetic Pickups (MPU)
Trip Response Time < 12 ms (Deterministic Hardware Trip)
Relay Outputs Redundant Form-A / Form-C Safety Relays
User Interface 3 Independent LCD Screens with Tactile Keypads
Communication Modbus RTU, CANbus, RS-232, RS-485
Enclosure Lockable, vibration-resistant industrial metal housing

Industrial Drives & Governors Properties

The Woodward 9907-147 is engineered with dedicated thermal heat sink dissipation profiles integrated across its three independent processing cores to prevent thermal drift. This module maintains an ultra-low latency actuator loop feedback response, forcing relay contact transition within 12 ms of an verified overspeed excursion. The internal hardware architecture processes continuous input variables from three separate magnetic pickups over an independent 2-out-of-3 (2oo3) voting matrix, computing real-time rotor velocity trends without software-induced execution delays.

Frequently Asked Questions

Q: How does the De-Energize-to-Trip (DET) configuration behave during a total loss of input power?

A: The internal safety relays are continuously energized during standard safe turbine operation. In the event of a total 24 VDC power loss, field wire rupture, or internal hardware malfunction, the contacts immediately drop out to execute a fail-safe mechanical shutdown sequence.

Q: What is the configuration structure of the integrated user interface?

A: The hardware features three independent LCD screens paired with distinct tactile keypads. Each display link maps directly to one of the internal redundant CPU channels, enabling local monitoring, configuration verification, and diagnostic tracking per channel without interrupting the voting logic.

Q: What digital network interfaces are available for distributed supervisory control?

A: The system supports simultaneous remote data transmission via native Modbus RTU, CANbus, RS-232, and RS-485 interfaces. This multi-port communication topology facilitates the routing of trip logs, diagnostic alarms, and live pulse telemetry to external DCS or SCADA stations.

Field Installation Guidelines

  • Enclosure Assembly Mounting: Bolt the lockable, industrial metal housing securely onto a clean vertical frame inside the instrument enclosure. Ensure the mounting fasteners are torqued to resist localized machine vibrations and maintain stable structural integrity.
  • Magnetic Pickup Wiring Routing: Use separate twisted, double-shielded pairs for each of the three independent MPU inputs. Run these sensor lines through dedicated conduits away from heavy current AC supply lines or inductive breaker switching paths to isolate against electromagnetic noise.
  • Shield Grounding Matrix: Connect the cable shields to the local instrumentation ground bus bar at the panel side only. Do not ground both ends of the shield to prevent the formation of ground loops that could introduce signal distortion into the speed sensing paths.
  • Safety Relay Termination: Connect the Form-A or Form-C trip relay circuits using conductor gauges sized to handle the peak inductive load of the trip solenoid. Install transient voltage suppression components across external DC inductive loads to protect the physical contacts from degradation.

9907-147 Woodward ProTech-203 Datasheet & Technical Manual

Item no : 58189571517
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 27 - Jul 2

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches